Wall and ceiling expansion joints
This full range of structural expansion joints for use in facades, walls and ceilings offers a solution for each configuration: inside or outside installation, standard or seismic expansion joint. All our expansion joints for walls, facades and ceiling are compatible with our fire-stop systems.
JSV 4-02
- MATERIAL : ALUMINIUM
- COLOR: NATURAL, RAL COLORS
- VERSION : FLAT & ANGLE.
- Seismic expansion joint
- Vertical installation on facade, wall and ceiling
- For joint gaps from 50 to 200 mm
DESCRIPTION:
All-aluminium vertical expansion joint for facades, comprising pre-drilled aluminium side sections and an interchangeable section in the center, able to take up large multi-directional movements. A waterproof membrane is available to ensure protection against the elements. Specially suitable for quality finish requirements and for wide joints with large seismic movements.
Installation:
For vertical joints in facades with a gap up to 200 mm (larger dimensions available on request).
COMPOSING:
Section length of 3 lm. Aluminium side and central sections. Nit-rile membrane
ALUMINIUM
Material | Aluminium 6060 | Aluminium 6063 |
Density | 2,7 | 2,7 |
Elongation at break | min. 160 MPa | min. 215 MPa |
Breaking limit | min. 215 MPa | min. 245 MPa |
Elongation | min. 6 % | min. 6 % |
Thermal conductivity at 20°C | 190 W / m.°C | 190 W / m.°C |
Modulus of elasticity | 70.000 MPa | 70.000 MPa |
Modulus of rigidity | 27.000 MPa | 27.000 MPa |
Value by Poisson | 0,33 | 0,33 |
Fire resistance | A 1 | A 1 |
Nitrile
Material | Nitrile DIN 18541 | Test Method |
Shore A hardness | 67 ± 5 | ISO 868 |
Density | 1,25 | ISO R 1183 |
Tensile strength | ≥ 10 MPa | ISO R 527-2 |
Elongation at break | ≥ 350 % | ISO R 527-2 |
Elongation at tear at 23°C | ≥ 350 % | DIN 53504 |
Tear-growth resistance | ≥ 14 MPa | DIN 53504 |
Linear tolerance | ± 0,7 % | DIN 16941 |
Linear expansion coefficient | 15 – 17 x 10-5 K -1 | DIN 53752 |
Fire resistance | B2 | B2 |
REFERENCE | GAP (MM) | MOVEMENTS (MM) | VISIBLE WIDTH (MM) | TOTAL WIDTH (MM) | HEIGHT (MM) |
JSV 4.02 | W | S | B | H | |
4.02-040 | 40 | 25/-25 | 114 | 114 | 15,7 |
4.02-040 A | 40 | 12,5/-12,5 | 61 | 77 | 15,7 |
4.02-050 | 50 | 39/-39 | 151 | 151 | 15,7 |
4.02-050 A | 50 | 19,5/-19,5 | 85 | 101 | 15,7 |
4.02-060 | 60 | 39/-39 | 161 | 161 | 15,7 |
4.02-060 A | 60 | 19,5/-19,5 | 95 | 111 | 15,7 |
4.02-080 | 80 | 39/-39 | 181 | 181 | 15,7 |
4.02-080 A | 80 | 19,5/-19,5 | 115 | 131 | 15,7 |
4.02-100 | 100 | 39/-39 | 201 | 201 | 15,7 |
4.02-100 A | 100 | 19,5/-19,5 | 135 | 151 | 15,7 |
4.02-120 A | 120 | 39/-39 | 221 | 221 | 15,7 |
4.02-120 A | 120 | 19,5/-19,5 | 155 | 171 | 15,7 |
4.02-150 | 150 | 39/-39 | 251 | 251 | 15,7 |
4.02-150 A | 150 | 19,5/-19,5 | 185 | 201 | 15,7 |
4.02-180 | 180 | 39/-39 | 281 | 281 | 15,7 |
4.02-180 A | 180 | 19,5/-19,5 | 215 | 231 | 15,7 |
4.02-200 | 200 | 39/-39 | 301 | 301 | 15,7 |
4.02-200 A | 200 | 19,5/-19,5 | 235 | 251 | 15,7 |
The load-bearing capacity is always indicated for a joint in its initial position. In case of opening movements, the load-bearing capacity significantly reduces and the product will thus be only adapted for a light pedestrian traffic. The indicated load-bearing capacities are based on pneumatic wheels vehicles with a contact surface of 200×200 mm.
JSV 4-04
- MATERIAL : GALVANIZED STEEL, NITRILE.
- COLORS : BLACK, GREY, RAL COLORS
- VERSION : FLAT & ANGLE.
- Seismic expansion joint
- Under plaster installation
- For joint gaps from 30 to 50 mm
DESCRIPTION:
Vertical expansion joint for facades, walls and ceilings, comprising two pre-drilled galvanized steel sections and an interchangeable flexible insert, able to take up large multi-directional movements. Specially suitable for use with surface rendering.
Installation:
For wall and ceiling joints with a gap up to 50 mm. Practical and easy to install
COMPOSING:
Section length of 3 m. Galvanized steel side angle sections. Top quality flexible PVC insert (flex)
PVC
Material | flex smooth PVC | Rigid PVC |
Shore hardness | 75 ± 5 | – |
Density | 1.14 | 1.52 |
Vicat fusion point | – | 80 °C |
Tensile strength | ≥ 8 MPa | 65 MPa |
Elongation at break | ≥ 275 % | 65% |
Elongation at tear at 23°C | ≥ 275 % | – |
Tear-growth resistance | ≥ 12 MPa | – |
Linear tolerance | ± 0.7 % | ± 0.7 % |
Linear expansion coefficient | 15 – 17 x 10-5 K-1 | 8 x 10-5 K-1 |
Fire resistance | B 2 | B2 |
Modulus of elasticity | – | 3200 MPa |
Water absorption | – | 0.04% |
Galvanized-steel
Material | Acier S235JR | Galvanisation DX51D + Z275 |
Modulus of elasticity | 235 MPa | – |
Value by Poisson | 0,3 | – |
Density | 7,8 | – |
Elongation at break | 340 MPa | – |
Zinc quantity | – | 275 g/m2 |
Thickness | – | 20 µ |
FINISHES AND SPECIAL PIECES:
Flat and corner. Black, grey or off-white insert.
REFERENCE | GAP
(MM) |
MOVEMENT
(MM) |
VISIBLE WIDTH (MM) | TOTAL WIDTH (MM) | HEIGHT (MM) |
JSV 4.04 | W | S | B | H | |
4.04-030 | 30 | 5 / -2 | 37 | 137 | 11 / 14 / 20 |
4.04-050 | 50 | 10 / -6 | 67 | 163 | 11 / 14 / 20 |
The load-bearing capacity is always indicated for a joint in its initial position. In case of opening movements, the load-bearing capacity significantly reduces and the product will thus be only adapted for a light pedestrian traffic. The indicated load-bearing capacities are based on pneumatic wheels vehicles with a contact surface of 200×200 mm.
JSV 4-06
- MATERIAL : ALUMINIUM, NITRILE.
- FINISHES : BLACK, GREY, RAL COLORS
- VERSION : FLAT & ANGLE.
- Seismic expansion joint
- Vertical installation on facade, wall and ceiling
- For joint gaps up to 350 mm
DESCRIPTION:
Vertical expansion joint for wall, ceiling and facade for joint gaps up to 350 mm. This seismic expansion joint allows large multi-directional movements. Available in flat and angle versions
COMPOSING:
Section length of 3 lm. Aluminium side and central sections. Nitrile membrane
ALUMINIUM
Material | Aluminium 6060 | Aluminium 6063 |
Density | 2,7 | 2,7 |
Elongation at break | min. 160 MPa | min. 215 MPa |
Breaking limit | min. 215 MPa | min. 245 MPa |
Elongation | min. 6 % | min. 6 % |
Thermal conductivity at 20°C | 190 W / m.°C | 190 W / m.°C |
Modulus of elasticity | 70.000 MPa | 70.000 MPa |
Modulus of rigidity | 27.000 MPa | 27.000 MPa |
Value by Poisson | 0,33 | 0,33 |
Fire resistance | A 1 | A 1 |
Nitrile
Material | Nitrile DIN 18541 | Test Method |
Shore A hardness | 67 ± 5 | ISO 868 |
Density | 1,25 | ISO R 1183 |
Tensile strength | ≥ 10 MPa | ISO R 527-2 |
Elongation at break | ≥ 350 % | ISO R 527-2 |
Elongation at tear at 23°C | ≥ 350 % | DIN 53504 |
Tear-growth resistance | ≥ 14 MPa | DIN 53504 |
Linear tolerance | ± 0,7 % | DIN 16941 |
Linear expansion coefficient | 15 – 17 x 10-5 K -1 | DIN 53752 |
Fire resistance | B2 | B2 |
REFERENCE | GAP (MM) |
MOVEMENTS (MM) |
VISIBLE WIDTH (MM) | TOTAL WIDTH (MM) | HEIGHT (MM) |
JSV 4.06 | W | S | B | H | |
4.06-030 | 30 | 8 / -2 | 120 | 120 | 15 |
4.06-050 | 50 | 20 / -10 | 140 | 140 | 15 |
4.06-080 | 80 | 35 / -15 | 170 | 170 | 15 |
4.06-120 | 120 | 45 / -20 | 210 | 210 | 15 |
4.06-200 | 200 | 50 / -40 | 290 | 290 | 15 |
4.06-280 | 280 | 80 / -45 | 370 | 370 | 15 |
4.06-350 | 350 | 100 / -50 | 440 | 440 | 15 |
The load-bearing capacity is always indicated for a joint in its initial position. In case of opening movements, the load-bearing capacity significantly reduces and the product will thus be only adapted for a light pedestrian traffic. The indicated load-bearing capacities are based on pneumatic wheels vehicles with a contact surface of 200×200 mm.
JSV 4-08
- MATERIAL : PVC, NITRILE.
- FINISHES : WHITE.
- VERSION : FLAT & ANGLE.
- Vertical expansion joint
- Special external insulation
- For joint gaps of 30 mm
DESCRIPTION:
Expansion joint profile especially designed for buildings with external thermal insulation. This profile is composed by : A fiber mesh-strip for a better adhesion, a nitrile sealing layer for waterproofing and UV resistant PVC profiles trim
Installation:
For vertical joints in façades with a gap up to 30 mm.
COMPOSING:
Section length of 2.5 m. Rigid PVC side and central sections. Nitrile membrane.
PVC
Material | flex smooth PVC | Rigid PVC |
Shore hardness | 75 ± 5 | – |
Density | 1.14 | 1.52 |
Vicat fusion point | – | 80 °C |
Tensile strength | ≥ 8 MPa | 65 MPa |
Elongation at break | ≥ 275 % | 65% |
Elongation at tear at 23°C | ≥ 275 % | – |
Tear-growth resistance | ≥ 12 MPa | – |
Linear tolerance | ± 0.7 % | ± 0.7 % |
Linear expansion coefficient | 15 – 17 x 10-5 K-1 | 8 x 10-5 K-1 |
Fire resistance | B 2 | B2 |
Modulus of elasticity | – | 3200 MPa |
Water absorption | – | 0.04% |
Nitrile
Material | Nitrile DIN 18541 | Test Method |
Shore A hardness | 67 ± 5 | ISO 868 |
Density | 1,25 | ISO R 1183 |
Tensile strength | ≥ 10 MPa | ISO R 527-2 |
Elongation at break | ≥ 350 % | ISO R 527-2 |
Elongation at tear at 23°C | ≥ 350 % | DIN 53504 |
Tear-growth resistance | ≥ 14 MPa | DIN 53504 |
Linear tolerance | ± 0,7 % | DIN 16941 |
Linear expansion coefficient | 15 – 17 x 10-5 K -1 | DIN 53752 |
Fire resistance | B2 | B2 |
REFERENCE | GAP (MM) | MOVEMENTS (MM) | VISIBLE WIDTH (MM) | TOTAL WIDTH (MM) | HEIGHT (MM) |
JSV 4.08 | W | S | B | H | |
4.08-030 | 30 | 5 / -5 | 32 | 285 | 50 |
The load-bearing capacity is always indicated for a joint in its initial position. In case of opening movements, the load-bearing capacity significantly reduces and the product will thus be only adapted for a light pedestrian traffic. The indicated load-bearing capacities are based on pneumatic wheels vehicles with a contact surface of 200×200 mm.
JSV 4-10
- MATERIAL : ALUMINIUM.
- FINISHES : NATURAL, RAL COLORS.
- VERSION : FLAT & ANGLE.
- Expansion joint special wide seismic movements
- Vertical installation on facade, wall and ceiling
- For joint gaps from 50 to 200 mm
DESCRIPTION:
All metal vertical seismic expansion joint for train stations, airports, shopping center… This range is design with springs to allow seismic movements.
COMPOSING:
Aluminium
ALUMINIUM
Material | Aluminium 6060 | Aluminium 6063 |
Density | 2,7 | 2,7 |
Elongation at break | min. 160 MPa | min. 215 MPa |
Breaking limit | min. 215 MPa | min. 245 MPa |
Elongation | min. 6 % | min. 6 % |
Thermal conductivity at 20°C | 190 W / m.°C | 190 W / m.°C |
Modulus of elasticity | 70.000 MPa | 70.000 MPa |
Modulus of rigidity | 27.000 MPa | 27.000 MPa |
Value by Poisson | 0,33 | 0,33 |
Fire resistance | A 1 | A 1 |
REFERENCE | GAP (MM) | MOVEMENTS (MM) | VISIBLE WIDTH (MM) | TOTAL WIDTH (MM) | HEIGHT (MM) |
JSV 4.10 | W | S | B | H | |
4.10-050 | 50 | 25 / -25 | 170 | 170 | 16,5 |
4.10-050 A | 50 | 25 / -25 | 110 | 110 | 16,5 |
4.10-100 | 100 | 50 / -50 | 220 | 220 | 16,5 |
4.10-100 A | 100 | 50 / -50 | 160 | 160 | 25 |
4.10-150 | 150 | 75 / -75 | 270 | 270 | 25 |
4.10-150 A | 150 | 75 / -75 | 210 | 210 | 25 |
4.10-200 | 200 | 100 / -100 | 320 | 320 | 25 |
4.10-200 A | 200 | 100 / -100 | 260 | 260 | 25 |
The load-bearing capacity is always indicated for a joint in its initial position. In case of opening movements, the load-bearing capacity significantly reduces and the product will thus be only adapted for a light pedestrian traffic. The indicated load-bearing capacities are based on pneumatic wheels vehicles with a contact surface of 200×200 mm.
JSV 4-12
- MATERIAL : ALUMINIUM.
- FINISHES : NATURAL, RAL COLORS.
- VERSION : FLAT & ANGLE.
- Expansion joint special wide seismic movements
- Vertical installation on facade, wall and ceiling
- For joint gaps from 50 to 200 mm
DESCRIPTION:
All metal seismic expansion joint for ceilings. Flat and angle models are available
COMPOSING:
Aluminium
ALUMINIUM
Material | Aluminium 6060 | Aluminium 6063 |
Density | 2,7 | 2,7 |
Elongation at break | min. 160 MPa | min. 215 MPa |
Breaking limit | min. 215 MPa | min. 245 MPa |
Elongation | min. 6 % | min. 6 % |
Thermal conductivity at 20°C | 190 W / m.°C | 190 W / m.°C |
Modulus of elasticity | 70.000 MPa | 70.000 MPa |
Modulus of rigidity | 27.000 MPa | 27.000 MPa |
Value by Poisson | 0,33 | 0,33 |
Fire resistance | A 1 | A 1 |
REFERENCE | GAP (MM) | MOVEMENTS (MM) | VISIBLE WIDTH (MM) | TOTAL WIDTH (MM) | HEIGHT (MM) |
JSV 4.12 | W | S | B | H | |
4.12-050 | 50 | 25 / -25 | 170 | 170 | 16,5 |
4.12-050 A | 50 | 25 / -25 | 110 | 110 | 16,5 |
4.12-100 | 100 | 50 / -50 | 220 | 220 | 16,5 |
4.12-100 A | 100 | 50 / -50 | 160 | 160 | 16,5 |
4.12-150 | 150 | 75 / – 75 | 270 | 270 | 17,5 |
4.12-150 A | 150 | 75 / – 75 | 210 | 210 | 17,5 |
4.12-200 | 200 | 100 / – 100 | 320 | 320 | 17,5 |
4.12-200 A | 200 | 100 / – 100 | 260 | 260 | 17,5 |
The load-bearing capacity is always indicated for a joint in its initial position. In case of opening movements, the load-bearing capacity significantly reduces and the product will thus be only adapted for a light pedestrian traffic. The indicated load-bearing capacities are based on pneumatic wheels vehicles with a contact surface of 200×200 mm.
JSV 4-14
- MATERIAL : ALUMINIUM, NITRILE.
- FINISHES : BLACK, GREY.
- VERSION : FLAT & ANGLE.
- Seismic expansion joint
- Special suspended ceilings
- For joint gaps from 30 to 100 mm
DESCRIPTION:
Expansion joint for false ceilings, comprising aluminium side sections and an interchangeable insert in the center, able to take up large multi-directional movements. Specially suitable for suspended ceilings.
INSTALLATION:
For joints in false ceilings or suspended ceilings with a gap up to 350 mm.
FINISHES AND SPECIAL PIECES:
Flat and corner (E). Black or gray insert. Other RAL colors available on request.
COMPOSING:
Section length of 4 m. Aluminium side angle sections. Top quality flexible PVC insert(flex).
ALUMINIUM
Material | Aluminium 6060 | Aluminium 6063 |
Density | 2,7 | 2,7 |
Elongation at break | min. 160 MPa | min. 215 MPa |
Breaking limit | min. 215 MPa | min. 245 MPa |
Elongation | min. 6 % | min. 6 % |
Thermal conductivity at 20°C | 190 W / m.°C | 190 W / m.°C |
Modulus of elasticity | 70.000 MPa | 70.000 MPa |
Modulus of rigidity | 27.000 MPa | 27.000 MPa |
Value by Poisson | 0,33 | 0,33 |
Fire resistance | A 1 | A 1 |
REFERENCE | GAP (MM) | MOVEMENTS (MM) | VISIBLE WIDTH (MM) | TOTAL WIDTH (MM) | HEIGHT (MM) |
JSV 4.14 | W | S | B | H | |
4.14-030 | 30 | 8 / – 2 | 60 | 60 | 50 |
4.14-050 | 50 | 20 / – 10 | 80 | 80 | 50 |
4.14-080 | 80 | 30 / – 15 | 110 | 110 | 50 |
4.14-100 | 100 | 45 / – 20 | 130 | 130 | 50 |
The load-bearing capacity is always indicated for a joint in its initial position. In case of opening movements, the load-bearing capacity significantly reduces and the product will thus be only adapted for a light pedestrian traffic. The indicated load-bearing capacities are based on pneumatic wheels vehicles with a contact surface of 200×200 mm.